CONNECTION AND SETUP
9
2.8 Examining DCCS Signal Transmission
Note: Needed only when the camera connected to CH1 supports DCCS.
Check the channel status bar of CH1, and see if the status icon of DCCS connection is “ ”.
If yes, the connection is ok.
If you see “
”, make sure:
- The distance between this DVR and the DCCS camera should not exceed 200 meters with a 3C2V coaxial cable (112
braids).
Note: However, different materials used in 3C2V coaxial cables with different connection distance may
cause some effects for the availability and fluency of signal transmission.
- It’s not allowed to use a signal booster or modem to amplify signals and extend the connection distance.